SRX
Usage
They keep the large pipes /tanks without insulation,down to -40 °C.
These heating cables are highly flexible and perfect for short heating circuits. As temperatures increase, the heater 's resistance increases which lowers the output wattage.
It constructed of a semi-conductive heater matrix extruded between parallel buss wires. It can be cut-to-length according to practical requirements.
It will not overheat or burnout even when overlapped.
Product Struction
Advantages & Applications
Technical Data
Product Struction
• Output Wattage: |
15,30, 45, 60(W/m) at 10°C |
|
• Maximum Un-energized temperature: |
200°C |
|
• Maximum Energized temperature: |
135°C |
|
• Minimum installation temperature: |
-40°C |
|
• Work voltage: |
220V-240V |
|
SRX Series |
SRX2: |
No tinned copper metal &outer |
|
SRX2-C |
Nickel plated copper braid |
|
SRX2-CF |
Nickel plated copper braid and fluoropolymer outjacket |
Partial view:
1.19*0.32 Nickel plated copper wire. |
2.Self-regulating conductive core. |
3. Thermoplastic insulation. |
4.Tinned copper braid |
5.Fluoroplymer outer jacket |
Advantages
Easier installation, can be cut to any length (up to maximum circuit length) required on site with no wasted cable.
Lower installation cost than steam tracing and less maintenance expense as well as less downtime.
No overheat or burnout even when overlapped itself.
Ready to be used in non-hazardous, hazardous and corrosive environments.
SRX is ideally used for process maintenance and freeze protection of pipelines,tanks and other industrial application where high temperature is needed. It is suitable for hazardous area, also non-hazardous area and corrosive area. Fluoroplymer outer jacket will ensure products in good condition.
Technical Data
SRX Series: |
Output Power@+ 10°C(W/m) |
Maximum Energized |
Maximum Un- energized |
Max length@0°C |
Max length@- 20°C 16/20A(m) |
Size (mm) |
Weight((kg/km) |
15SRX2CF |
15 |
135°C |
200°C |
70/102/- |
78/94/- |
10.1*5.1 |
98 |
30SRX2CF |
30 |
135°C |
200°C |
60/78/- |
60/90/- |
10.1*5.1 |
98 |
45SRX2CF |
45 |
135°C |
200°C |
54/65/- |
46/67/75 |
10.1*5.1 |
98 |
60SRX2CF |
60 |
135°C |
200°C |
42/66/76- |
36/52/62 |
10.1*5.1 |
98 |