Our in-screed heating cable is a twin-conductor floor heating cable with metal ground wire, the outside diameter is 5.0 mm and rated at 20w/m
It cannot be cut in any situation because the length and the output of the constant wattage cable are determinated
The in-screed heating cable is suitable for providing energy-efficient indoor underfloor heating and can be installed under almost any floor coverings
it is excellent for simple installation of any size and adds no build height to the construction
Product Struction
Advantages & Applications
Technical Data
Product Struction
• Cable construction: |
Twin conductor |
• Twin conductor |
Solid heating core |
• Insulation |
Fluoroplastic |
• Protective jacket: |
PVC |
• Connector: |
Out splice |
• Outside diameter: |
5.0mm |
• Rated voltage: |
220V-240V |
• Linear power: |
20W/m |
• Resistance tolerance: |
+10/-5 % |
Advantages
Twin conductor design,only one cold lead,ease of installation.
Metal conductor,no wattage lose.
Teflon insulation,max maintain 200℃,high insulation resistance.
100% Aluminum foil shield,zero EMR .
Metal ground wire, keep you safe.
Waterproof IP68.
25 years limited warranty against manufacturing defects.
Technical Data
Part NO. |
Wattage (w) |
length(m) |
Resistance(Ω) |
X-cable 20-200 |
200 |
10 |
242.00 |
X-cable 20-300 |
300 |
15 |
161.33 |
X-cable 20-400 |
400 |
20 |
121.00 |
X-cable 20-500 |
500 |
25 |
96.80 |
X-cable 20-600 |
600 |
30 |
80.67 |
X-cable 20-700 |
700 |
35 |
69.14 |
X-cable 20-850 |
850 |
42.5 |
56.94 |
X-cable 20-1000 |
1000 |
50 |
48.40 |
X-cable 20-1200 |
1200 |
60 |
40.33 |
X-cable 20-1400 |
1400 |
70 |
34.57 |
X-cable 20-1600 |
1600 |
80 |
30.25 |
X-cable 20-1800 |
1800 |
90 |
26.89 |
X-cable 20-2000 |
2000 |
100 |
24.20 |
X-cable 20-2200 |
2200 |
110 |
22.00 |
X-cable 20-2400 |
2400 |
120 |
20.17 |
X-cable 20-2600 |
2600 |
130 |
18.62 |
X-cable 20-2800 |
2800 |
140 |
17.29 |
X-cable 20-3100 |
3100 |
155 |
15.61 |